Name:Insertion-type Ultrasonic Heat Meter
Model:LRF-3000SC-R
Size:210*160*63mm
 
 
General Introduction:
LRF-3000SC-R is high-end wall mounted ultrasonic flow meter with insertion transducers . It adopts our self-developed TGA measurement technology. Compared with the commonly used TDC calculation method used by most of our domestic manufacturers ,TGA measurement technology is an algorithm for measuring process time with higher speed and accuracy.
 
 
 
Features:
Compared with other conventional flow/heat meters, LRF-3000S has other unique features besides the common features such as high flexibility of field installation, high response speed and better measurement ability under low flow rate:
1.  Adopts high performance FPGA chip with independent 400,000 gate array. Measurement rate can be more than 300 times per second, which greatly improves the tolerance rate of bubbles in the measured pipe compared with other brands. It can withstand continuous bubbles for up to 5 seconds.
2.  Increased signal strength has greater penetration ability to all kinds of scale, rust and pipe lining.
3.  4 lines dot matrix LCD screen. Chinese/English menu selectable. Easy to be operated.
4.  Transducers adopt our special manufacturing process and matching technology. Zero-point range can be controlled within 0.03m/s. Time difference between each pair of static sensors is less than 2 nanoseconds, which effectively ensures the authenticity of the measured time difference.
 
 
 
 


Selection code:
Model Transmitter
LRF-3000S Ultrasonic flowmeter
Wall mount
Flow range:±0.09ft/s ~ ±39ft/s (±0.03m/s ~ ±12m/s)
Accuracy :±1% of the measure value
Repeatability:0.2% of the measure value
Display:240*128 backlit LCD
Power supply: 10 ~ 36VDC or 10~240V
Transmitter enclosure: IP65, ABS (Temperature: -20℃~50℃)
Output: OCT pulse output 0-10KHz, Relay output, 4-20mA
optional
Communication: RS485/RS232, Modbus Protocol  (M-BUS or HART optional)
Code Output
1 OCT,Relay,RS232/RS485,4-20mA(Flow meter)
2 OCT,Relay,RS232/RS485,4-20mA,RTD(Heat meter)
Code Transducer
TT05 plug-in, IP68. Operating temperature:
-40 ℉ ~ +176 ℉(-40℃ ~ +80 ℃)(Standard)
plug-in, IP68. Operating temperature:
-40 ℉ ~ +266℉(-40℃ ~ +130 ℃)(High Temp)
XXX Transducer cable length
030 Standard length 30ft (9m)
XXX Max length to 1000ft (300m)
Code Temperature sensor
PT1000 Pt1000 temperature sensor+RTD module(selectable)
Code Memory
SD SD card(32G)+ SD card module(selectable)

Transmitter:
Split-inline-type ultrasonic heat meter
Main Parts:
Split-inline-type ultrasonic heat  meter
Installation diagram:
Split-inline-type ultrasonic  heat meter
 
Performance specification
Flow range 0 m/s ~± 12 m/s
Accuracy ±1.0%
Repeatability 0.2%
Pipe Size DN100mm above universal
Function Specification
Outputs Analog output: 4~20mA, max load 750Ω.
Pulse output: 0~10KH
Relay output:Max. frequency :1Hz(1A@125VAC或2A@30VDC)
Communication  RS485/RS232, Modbus Protocol  (M-BUS or HART optional)
SD Card
(selectable)
32G,512 天
Interval time : 1 ~ 99999 secends(configurable)
Power Supply 10 ~ 36VDC or 10~240V
Keypad 16 keys(4X4) touch keys
Display 240*128, 4-line LCD display
Temperature Transmitter: -14℉~140℉(-20℃~60℃)
Transducer:-40℉~176℉(-40℃~80℃,TT01  ,Standard)
Transducer:-40℉~266℉(-40℃~130℃,TT03  ,High Temp)
Humidity Up to 0 ~ 99% RH, non - condensing.
Physical specification
Transmitter PC/ABS, IP65
Transducer Real 304 stainless steel material, patented aviation plug design
Protection grade IP68, can work under water
Standard/maximum cable length:30ft/1000ft(9m/300m)
packaging 20*22*23.5cm, 3.0kg